255 research outputs found

    Physical limitations to the spatial resolution of solid-state detectors

    Full text link
    In this paper we explore the effect of δ\delta-ray emission, fluctuations in th e signal deposition on the detection of charged particles in silicon-based detec tors. We show that these two effects ultimately limit the resolution that can be achieved by interpolation of the signal in finely segmented position-sensitive solid-state devices.Comment: 5 page

    Multiple Classifier Systems for the Classification of Audio-Visual Emotional States

    Full text link
    Abstract. Research activities in the field of human-computer inter-action increasingly addressed the aspect of integrating some type of emotional intelligence. Human emotions are expressed through differ-ent modalities such as speech, facial expressions, hand or body gestures, and therefore the classification of human emotions should be considered as a multimodal pattern recognition problem. The aim of our paper is to investigate multiple classifier systems utilizing audio and visual features to classify human emotional states. For that a variety of features have been derived. From the audio signal the fundamental frequency, LPC-and MFCC coefficients, and RASTA-PLP have been used. In addition to that two types of visual features have been computed, namely form and motion features of intermediate complexity. The numerical evaluation has been performed on the four emotional labels Arousal, Expectancy, Power, Valence as defined in the AVEC data set. As classifier architec-tures multiple classifier systems are applied, these have been proven to be accurate and robust against missing and noisy data.

    The state of the focus and image quality of the Spitzer Space Telescope as measured in orbit

    Get PDF
    We describe the process by which the NASA Spitzer Space Telescope (SST) Cryogenic Telescope Assembly (CTA) was brought into focus after arrival of the spacecraft in orbit. The ground rules of the mission did not allow us to make a conventional focus sweep. A strategy was developed to determine the focus position through a program of passive imaging during the observatory cool-down time period. A number of analytical diagnostic tools were developed to facilitate evaluation of the state of the CTA focus. Initially, these tools were used to establish the in-orbit focus position. These tools were then used to evaluate the effects of an initial small exploratory move that verified the health and calibration of the secondary mirror focus mechanism. A second large move of the secondary mirror was then commanded to bring the telescope into focus. We present images that show the CTA Point Spread Function (PSF) at different channel wavelengths and demonstrate that the telescope achieved diffraction limited performance at a wavelength of 5.5 μm, somewhat better than the level-one requirement

    Performance studies of the Belle II Silicon Vertex Detector with data taken at the DESY test beam in April 2016

    Get PDF
    Belle II is a multipurpose detector currently under construction which will be operated at the next generation B-factory SuberKEKB in Japan. Its main devices for the vertex reconstruction are the Silicon Vertex Detector (SVD) and the Pixel Detector (PXD). In April 2016 a sector of the Belle II SVD and PXD have been tested in a beam of high energetic electrons at the test beam facility at DESY Hamburg (Germany). We report here the results for the hit efficiency estimation and the measurement of the resolution for the Belle II silicon vertex etector. We find that the hit efficiencies are on average above 99.5% and that the measured resolution is within the expectations

    Performance studies of the Belle II Silicon Vertex Detector with data taken at the DESY test beam in April 2016

    Get PDF
    Belle II is a multipurpose detector currently under construction which will be operated at the next generation B-factory SuberKEKB in Japan. Its main devices for the vertex reconstruction are the Silicon Vertex Detector (SVD) and the Pixel Detector (PXD). In April 2016 a sector of the Belle II SVD and PXD have been tested in a beam of high energetic electrons at the test beam facility at DESY Hamburg (Germany). We report here the results for the hit efficiency estimation and the measurement of the resolution for the Belle II silicon vertex etector. We find that the hit efficiencies are on average above 99.5% and that the measured resolution is within the expectations

    Measurement of the Branching Fraction of the Decay B+π+π+ν\boldsymbol{B^{+}\to\pi^{+}\pi^{-}\ell^{+}\nu_\ell} in Fully Reconstructed Events at Belle

    Get PDF
    We present an analysis of the exclusive B+π+π+νB^{+}\to\pi^{+}\pi^{-}\ell^{+}\nu_{\ell} decay, where \ell represents an electron or a muon, with the assumption of charge-conjugation symmetry and lepton universality. The analysis uses the full Υ(4S)\Upsilon(4S) data sample collected by the Belle detector, corresponding to 711 fb1^{-1} of integrated luminosity. We select the events by fully reconstructing one BB meson in hadronic decay modes, subsequently determining the properties of the other BB meson. We extract the signal yields using a binned maximum-likelihood fit to the missing-mass squared distribution in bins of the invariant mass of the two pions or the momentum transfer squared. We measure a total branching fraction of B(B+π+π+ν)=[22.71.6+1.9(stat)±3.5(syst)]×105{{\cal B}(B^{+}\to \pi^{+}\pi^{-}\ell^{+}\nu_{\ell})= [22.7 ^{+1.9}_{-1.6} (\mathrm{stat}) \pm 3.5(\mathrm{syst}) ]\times 10^{-5}}, where the uncertainties are statistical and systematic, respectively. This result is the first reported measurement of this decay.Comment: 23 pages, 19 figure

    RBF-TSS: Identification of Transcription Start Site in Human Using Radial Basis Functions Network and Oligonucleotide Positional Frequencies

    Get PDF
    Accurate identification of promoter regions and transcription start sites (TSS) in genomic DNA allows for a more complete understanding of the structure of genes and gene regulation within a given genome. Many recently published methods have achieved high identification accuracy of TSS. However, models providing more accurate modeling of promoters and TSS are needed. A novel identification method for identifying transcription start sites that improves the accuracy of TSS recognition for recently published methods is proposed. This method incorporates a metric feature based on oligonucleotide positional frequencies, taking into account the nature of promoters. A radial basis function neural network for identifying transcription start sites (RBF-TSS) is proposed and employed as a classification algorithm. Using non-overlapping chunks (windows) of size 50 and 500 on the human genome, the proposed method achieves an area under the Receiver Operator Characteristic curve (auROC) of 94.75% and 95.08% respectively, providing increased performance over existing TSS prediction methods

    Performance of the multiband imaging photometer for SIRTF

    Get PDF
    We describe the test approaches and results for the Multiband Imaging Photometer for SIRTF. To verify the performance within a `faster, better, cheaper' budget required innovations in the test plan, such as heavy reliance on measurements with optical photons to determine instrument alignment, and use of an integrating sphere rather than a telescope to feed the completed instrument at its operating temperature. The tests of the completed instrument were conducted in a cryostat of unique design that allowed us to achieve the ultra-low background levels the instrument will encounter in space. We controlled the instrument through simulators of the mission operations control system and the SIRTF spacecraft electronics, and used cabling virtually identical to that which will be used in SIRTF. This realistic environment led to confidence in the ultimate operability of the instrument. The test philosophy allowed complete verification of the instrument performance and showed it to be similar to pre-integration predictions and to meet the instrument requirements

    Angular analysis of B0K(892)0+B^0 \to K^\ast(892)^0 \ell^+ \ell^-

    Full text link
    We present a measurement of angular observables, P4P_4', P5P_5', P6P_6', P8P_8', in the decay B0K(892)0+B^0 \to K^\ast(892)^0 \ell^+ \ell^-, where +\ell^+\ell^- is either e+ee^+e^- or μ+μ\mu^+\mu^-. The analysis is performed on a data sample corresponding to an integrated luminosity of 711 fb1711~\mathrm{fb}^{-1} containing 772×106772\times 10^{6} BBˉB\bar B pairs, collected at the Υ(4S)\Upsilon(4S) resonance with the Belle detector at the asymmetric-energy e+ee^+e^- collider KEKB. Four angular observables, P4,5,6,8P_{4,5,6,8}' are extracted in five bins of the invariant mass squared of the lepton system, q2q^2. We compare our results for P4,5,6,8P_{4,5,6,8}' with Standard Model predictions including the q2q^2 region in which the LHCb collaboration reported the so-called P5P_5' anomaly.Comment: Conference paper for LHC Ski 2016. SM prediction for P6P_{6}' corrected and reference for arXiv:1207.2753 adde
    corecore